32
Or
Ordering Guide
dering Guide
Hardware Configuration
Housing
metal housing
M
polycarbonate housing
P
Type
humidity + temperature
FT
Output
0-1V
1
0-5V
2
0-10V
3
4-20mA
6
Model
wall mounting - cable gland M16x1.5
cable Ø 4.5 - 10 mm
(0.18 - 0.39")
A
wall mounting - rear cable outlet
F
Probe
1 probe RH&T
1
2 separate probes for RH and T
2
Filter
membrane filter
1
stainless steel sintered filter
3
PTFE filter
5
metal grid filter (polycarbonate)
6
metal grid filter (stainless steel)
9
Display
without display
with display
D07
Plug
without plug
1 plug for power supply and outputs
C03
Sensor coating
without coating
with coating
HC01
Calibration
standard calibration
high humidity calibration
CA1
Software Configuration
T-Unit
°C
°F
E01
Scaling of T-output
-40...60 (T02)
0...120 (T16)
-20...50 (T48)
in°C or °F
-10...50 (T03)
-30...60 (T20)
-40...176 (T80)
0...50 (T04)
0...80 (T21)
0...140 (T85)
0...60 (T07)
-40...80 (T22)
0...176 (T86)
-30...70 (T08)
-20...80 (T24)
32...120 (T90)
-10...70 (T11)
-20...60 (T25)
32...140 (T91)
-40...120 (T12)
-30...50 (T45)
32...132 (T96)
Cable length
2m (6.6ft)
HA010801
5m (16.4ft)
HA010802
10m (32.8ft)
HA010803
EE22-
Position 1 - Transmitter
Position 2 - Probe cable
Select according to
Ordering Guide
(Txx)
Other T-scaling refer to
page 134
Accessories / R
Accessories / Reeplacement P
placement Par
arts
ts
(F
(For fur
or fur ther inf
ther infor
or ma
mation see da
tion see data sheet "
ta sheet "Accessories",
Accessories", pa
pagge 128)
e 128)
Or
Order Example
der Example
- Replacement probe RH&T in polycarbonate
(EE07-PFTx)
- probe cable 2m (6.6ft) / 5m (16.4ft) / 10m (32.8ft) (HA0108xx)
- Replacement probe T in polycarbonate
(EE07-PTx)
- bracket for rail installation
(HA010203)
- Replacement probe RH&T in metal
(EE07-MFTx)
- external supply unit
(V02)
- Replacement probe T in metal
(EE07-MT)
- RH calibration set
(HA0104xx)
- Display + housing cover in metal
(D07M)
- Reference probes
(HA010403)
- Display + housing cover in polycarbonate
(D07P)
- Filter caps
(HA0101xx)
Position 1 - Transmitter:
EE22-MFT2A26C03/T07
housing:
metal housing
type:
humidity + temperature
output:
0-5V
model:
wall mounting - cable gland M16x1.5
probe:
2 separate probes for RH and T
filter:
metal grid filter (polycarbonate)
display:
without display
plug:
1 plug for power supply and outputs
sensor coating:
without coating
calibration:
standard calibration
T-Unit:
°C
scaling of T-output:
0...60°C
EE22
Position 2 - Probe cable:
2x HA010802
cable length:
2x 5m (2x 16.4ft)